SECTION 6 − DYNASTY 210 OPERATION

6-1. Dynasty 210 Controls

1
7
8
1
Standby Button
Use to put machine into low power
consumption mode.
.
This button can also be used to clear
some errors. See Section 12-3.
2
Amperage Adjustment Control
Use control to change preset amperage
value. If a remote control is used, preset
amperage value is the maximum amperage
output available. This control also functions
as a parameter change control while in the
menu mode (see Sections 6-2 thru 6-6).
3
Memory Card Port And Indicator
This port is used to add features to the ma-
chine and update software to the boards
OM-270536 Page 32
.
A complete Parts List is available at www.MillerWelds.com
3
4
within the machine. Indicator is lit while card
is being accessed (see Section 5-12D).
4
Volt Meter
Displays actual rectified average voltage
when voltage is present at the weld output
terminals. It is also used to display para-
meter descriptions while in the menu.
5
Ammeter
Displays actual amperage while welding
and preset amperage while idle. It is also
used to display parameter selection op-
tions while in the menu.
6
Menu Button
Press button to scroll through available
parameters for the selected process. Hold
5
2
6
button to enter set-up mode (see Sections
6-2 thru 6-6).
7
Output ON Indicator
Blue indicator illuminates when output is
on.
8
Process Selector
Use to select one of the following pro-
cesses:
• AC TIG - Used for welding aluminum.
• DC TIG - (DCEN) Used for welding mild
and stainless steel.
• DC Stick - (DCEP) Used for welding
steels.
• AC Stick - Used for welding steels if arc
blow is a problem while using DC Stick.
The memory card port uses an SD
memory card.
The SD logo is a registered trademark
of SD-3C LLC.
247222-D