Sequencer And Weld Timer For Dx Model - Miller Dynasty 210 DX CPS Owner's Manual

Hide thumbs Also See for Dynasty 210 DX CPS:
Table of Contents

Advertisement

11-3. Sequencer And Weld Timer For DX Model

INTL
INTL
ISLP
FSLP
FNL
FNL
WELD
OM-270536 Page 60
.
A complete Parts List is available at www.MillerWelds.com
20A
OFF
OFF
OFF
10A
OFF
OFF
Sequencer Control With Weld Timers ON
This function is available while using the TIG
process, but is disabled if a remote foot or
fingertip control is connected while in the RMT
STD mode. When active, the sequencer
controls the following parameters of the weld
cycle:
Initial Amperage
Range is 2−210 amps AC,1−210 amps DC
Initial Time*
Range is OFF to 25.0T (seconds)
Initial Slope Time
Range is OFF to 50.0T (seconds)
Final Slope Time
Range is OFF to 50.0T (seconds)
Final Amperage
Range is 2−210 amps AC,1−210 amps DC
Final Time*
Range is OFF to 25.0T (seconds)
.
When a remote switch is connected to the
welding power source, use the remote switch
to control the weld cycle. Amperage is
controlled by the welding power source.
*enabled features with weld timer On (see Section
11-2).
Weld Timer
With Weld Timer enabled, press Amperage (A)
button, and turn amperage adjustment control to
set weld time. Range is Off or 0.1−99.9 and
100−999 (sec) (see Section 11-2).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents