Section 4 − Specifications; Serial Number And Rating Label Location; Software Licensing Agreement; Information About Default Weld Parameters And Settings - Miller Dynasty 210 DX CPS Owner's Manual

Hide thumbs Also See for Dynasty 210 DX CPS:
Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for the power source is located on the top of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula

4-3. Information About Default Weld Parameters And Settings

NOTICE − Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical welding
parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are for reference
purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriateness of all parameters
and settings should be evaluated and modified by the end user as necessary based upon application-specific requirements. The end user is solely
responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld parameters and settings, and ultimate
quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warranties including any implied warranty of fitness
for a particular purpose.

4-4. Specifications

.
This equipment will deliver rated output at an ambient air temperature up to 1045 F ( 405 C).
A. Dynasty
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-6, 5-8 and 5-9 for information on
connecting input power.
Welding Amperage Range
1-210*
*Welding range for Stick process is 5-210 amperes. For TIG, the amperage range is tungsten diameter dependent (see Sections 8-4 and/or
10-3) depending on model.
** Arc starting device is designed for manual guided operations.
*** Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
Process
Current
(A)
210
STICK
160
125
210
TIG
175
Idle OCV
0
Idle OCV
0
Idle w/ Output
Off
Standby
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
and are incorporated by reference herein.
Max Open Circuit Voltage (Uo)
80
Output Ratings
Duty
Voltage (V)
Cycle
28.4
30%
26.4
60%
25
100%
18.4
60%
17
100%
77.5
77.5
Low Open-Circuit Voltage (Uo)
8-15***
Current Draw (A)
At Rate Input Voltages (V)
Phase
208V
240V
1
40
34
3
23
20
1
29
25
3
17
15
1
22
18
3
13
11
1
28
24
3
16
14
1
22
19
3
13
11
Power Draw (W)
1
83
83
3
93
96
1
23
25
1
9
11
3
13
14
Rated Peak Striking Voltage
(Up)
15KV**
Input Power
400V
480V
kW
20
17
8.3
12
10
8.0
15
12
6.0
9
7
5.8
11
9
4.4
7
6
4.5
14
12
5.8
9
7
5.8
12
10
4.6
7
6
4.6
91
96
101
111
32
35
19
25
28
39
OM-270536 Page 13
kVA
8.3
8.4
6.0
6.1
4.5
4.6
5.8
6.0
4.6
4.8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents