6-6. Accessing User Setup Menu: AC And DC Stick

2
USER
HOTS
OUT
.
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
Or
ON
ON
1
Menu Button
Press and hold Menu button for ap-
proximately 2 seconds to access
machine configuration menus. Use
1
Menu button to cycle through para-
meters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment con-
trol to adjust parameter setting.
.
To exit menu, press and hold
Menu button until Menu Off is
displayed.
Arc Starting Method Selection:
[HOTS] [ON]
Provides additional amperage while striking the
electrode to prevent the electrode from sticking.
[HOTS OFF]
No additional starting amperage to assist in starting
the electrode.
Trigger Mode Selection:
[RMT] [STD]
Typically used with a remote foot or hand control.
RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled
with a remote potentiometer, or it can be set at the
control panel.
[OUT] [ON]
!
Weld output terminals are energized at all
times when displays read [OUT] [ON].
No remote control or trigger required. Amperage
can be controlled at the control panel or with a
remote potentiometer. Blue output on LED illu-
minates to indicate output is on.