6-4. Accessing Control Panel Menu: AC And DC Stick

2
DIG
Notes
.
A complete Parts List is available at www.MillerWelds.com
3
4
110A
110A
30%
1
Menu Button
Press Menu button to cycle through paramet-
ers that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
1
Rotate amperage adjustment control to adjust
parameter setting.
.
Parameter automatically returns to am-
perage setting 15 seconds after amperage
adjustment control is inactive.
Amperage Control:
Controls the welding amperage output. Limits the
maximum output of a remote amperage device.
In AC, the user will be setting the rectified average value
of the AC current. [AC AV]will be displayed.
[DIG]* Arc Force Control:
Controls the amount of additional amperage at low
voltage (short arc length) conditions. Adjust the force of
the arc for different joint configurations and electrodes.
Range is OFF−100%. Features PRO−SET values for
6010 and 7018 electrodes.
*PRO−SET
provides
PROfessionally
SETtings for the weld process. To use PRO−SET, press
the menu button to display the parameter and adjust the
amperage adjustment control until PRO−SET flashes on
the display. PRO−SET flashes one time and reveals the
professional setting for the parameter.
*CARB-ARC at one step above DIG's 100%, CARBon
ARC Gouging can be selected.
developed
247222-D
OM-270536 Page 35