General (Gen) Tungsten Programmable Tig Starting Parameters (Dx Models Only) - Miller Dynasty 210 DX CPS Owner's Manual

Hide thumbs Also See for Dynasty 210 DX CPS:
Table of Contents

Advertisement

17-3.

General (GEN) Tungsten Programmable TIG Starting Parameters (DX Models Only)

TUNG
Available Parameter Settings
Current (A)
Start Time
Parameter
• Start Output Polarity (POL)
• Start Amperage (STRT)
• Start Time (TIME)
• Start Slope (SSLP)
• Preset Minimum Amper-
age (PMIN)
OM-270536 Page 78
GEN
Start Slope Time
Default AC
• EP (Electrode Positive)
• 30 A
• 120 ms
• 120 ms
• 10 A
2
1
3
Preset Amperage Minimum
Default DC
• EN (Electrode Negative)
• 25 A
• 120 ms
• 100 ms
• 10 A
1
Amperage Adjustment Control
2
Parameter Display
3
Amperage Button
Once inside the machine set up
menu, tungsten parameter values
can be manually changed by press-
ing the Amperage switch pad to
step through each adjustable para-
meter. Turn amperage adjustment
control to change the value.
247220-D
Range
• EP / EN
• 5−200 A
• 0−250 ms
• 0−250 ms
• 1 (DC) 2 (AC) −25 A