Changing group of parameters

13
Parameter/
1 (default)
Group
Open/Close
15 minutes
Hold Open
Time
Kill mode
Locked
during kill
Obstruction
Door closer
1)
mode
Double
Separate
egress mode
presence
detection
Lock retry
On
Open/Close
In AUTO
impulse
mode
1)
If set to "Reverses when obstructed", the operator re-opens when obstructed, similar to a presence impulse.
As default the operator tries to close two times extra in automatic operation, Off or Exit mode and one time
in manual operation, Off or Exit mode if there is a problem with binding striking plates. This function can
be switched off (see "Lock retry" above).
42
1. Disconnect batteries if any.
2. Disconnect the mains contact.
3. Press the "Learn button (LRN)" and keep it depressed.
4. Connect the mains contact.
5. Watch the "Error LED".
3 s
1 s
5 s
6. Release the "Learn Button" after the 5 seconds (LED is out).
The "Error LED" flashes a number of short flashes that corresponds to the param-
eter group number (see table). After a short pause the LED will repeat the group
number, and so on.
7. Pushing the "Learn button" once, increases the parameter group number. When
the highest parameter group number is reached it will start with number 1
(default) again.
8. Push the button until you get the requested parameter group.
9. Disconnect the mains contact.
10. Next time the mains is connected, the operator will use the new group of parameters.
2
3
Infinite
Locked
during kill
Door closer
Separate
presence
detection
On
In AUTO
mode
Issue 2007-10-11
Changing group of parameters
4
5
15 minutes
15 minutes
Lock
Locked
follows
during kill
program
selector
during kill
Door closer Reverses
when
obstructed
Separate
Separate
presence
presence
detection
detection
On
On
In AUTO
In AUTO
mode
mode
6
7
15 minutes
15 minutes
Locked
Locked
during kill
during kill
Door closer Door closer Door closer
Common
Separate
presence
presence
detection
detection
On
Off
In AUTO
In AUTO
mode
mode
1003680-US-4.0
8
15 minutes
Locked
during kill
Separate
presence
detection
On
In OFF,
EXIT and
AUTO
mode

Hide quick links: