Table 26
Result
BERT BBE
BERT BBER
M.2100 ISM
Table 24
performance results in alphabetical order.
results
Table 27
Result
NE Verdict
NE ES
NE ESR
NE EFS
NE EFSR
HST-3000 E1 Testing User's Guide
Appendix A E1 BERT and Pulse Shape Test Results
G.826 OOS performance results (Continued)
Description
BERT Background Block Error. Number of
errored blocks that did not result in a SES.
BERT Background Block Error Ratio. The ratio
of available blocks to the number of blocks
received.
describes the M.2100 ISM (in service monitoring)
M.2100 ISM performance results
Description
Near End Verdict. Test status for the receive
direction.
"Accepted" indicates that the test results have
met the M.2100 performance objectives.
"Uncertain" indicates that the SES and ES
counts fall within the S1 <= n <= S2 range.
"Rejected" indicates that the test results did
not meet the performance objectives.
Near End Errored Seconds. The number of
available seconds during which one or more
relevant anomalies or defects were present.
Near End Errored Seconds Ratio. The ratio
errored seconds to the number of available
seconds.
Near End Error Free Seconds. The number of
available seconds during which no relevant
anomalies or defects were present.
Near End Error Free Seconds Ratio. The ratio
of error free seconds to the number of avail-
able seconds.