Philips AG1000 Service Manual page 47

Disc changer
Table of Contents

Advertisement

on the turntable, the position of the free end of the bracket (2) must be corrected by bending it upwards
or downwards. The PU-ARM is now set in such a way that when it is placed above the turntable, the
needle ​ j ust passes over the hairs of the felt​ . Care must be taken that the plastic disc ​ ( 2) -VIII​ does not
touch the blade (2a) -VIII when the needle is resting on the plate, otherwise the free horizontal
movement of the PU arm is impeded (mutual distance approx. 0.3 mm).
............
843582
2.
The friction of the taker (1) -VI is too large and needs to be adjusted. In order to do this, the PU-arm
must be placed on the support of the start switch, making it possible to ​ r each a screw​ ​
t hrough the hole
(​ 3 ​ ) in the mounting plate, with which the friction can be adjusted. If a ​ Y eard pressure meter​ is available,
the friction can be adjusted to 2 grams. This is measured on point
the center of the driver (1) -VI. If such an instrument ​ i s not available​ , the adjustment must take place in
the following manner​ .
47

Advertisement

Table of Contents
loading

Table of Contents