Configuration File
The various setting values can be stored in a file and resumed. The setting file storage location and
its name are "\Documents and Settings\System Settings\OBRDRV.ini". If there is no such the
setting file, the default values are used to initiate scanning.
Table 2.50
Symbol
Parameter
ogy
READCODE
CODE39_MIN
CODE39_MAX
CODE39_OUTFORMAT
Continue.
Description
Range
Enable or disable
scanning the
symbologies.
(note 1)
16384
32768
65536
Valid minimum digits
Valid maximum digits
Output format
56
Default
1
131071
1:
2
2:
4
4:
8
8:
16
16:
32
32:
64
64:
128
128:
256
256:
512
512:
1024
1024:
2048
2048:
4096
4096:
8192
8192:
16384:
32768
65536
2
2
52
52
0
0
0:
Output Code39 bar code
with start and stop
characters.
1
1:
Output Code39 bar code
without start and stop
characters.
2
2:
Output Code39 bar code
after Full ASCII conversion
and with start and stop
characters.
3
3:
Output Code39 bar code
after Full ASCII conversion
and without start and stop
characters.
Setting
Enable Code39
Enable NW-7
Enable WPC Addon
Enable WPC
Enable UPC-E Addon
Enable UPC-E
Enable IDF
Enable ITF
Enable Code93
Enable Code128
Enable MSI
Enable IATA
Enable GS1 DataBar
Omnidirectional.
Enable GS1 DataBar
Limited.
Enable GS1 DataBar
Expanded.
Enable GS1 DataBar
Stacked.
Enable GS1 DataBar
Expanded Stacked.