2.12 Power Control
This chapter describes about detailed specifications of the power controls.
2.12.1 Monitoring Low Voltage
Four levels of the low voltage monitor control are provided for the terminal.
Table 2.109
VDET1
VDET2
VDET3
VDETCF
Battery Pack
The following shows statuses and levels available for the battery pack.
Normally the battery status is checked once every five seconds. Taking last immediate ten data of
the power voltage from AD converter, its average is calculated to classify the status into three
levels, either "Almost exhausted (10% of the capacity or less)", "Low (30% of the capacity or
less)", "O.K. (30 % of the capacity or more)". When VDET1 occurs, the level is at 10% of the
capacity.
Table 2.110
Status/Level
Status
External
Recharge Recharging
Normal
Level
1
2
3
Description
Warning against low
voltage of the battery
pack
Turning off the power
due to low voltage of the
battery pack
Emergency turning off
the power due to low
voltage of the battery
pack
Turning off the power
due to low voltage of
card
Notation
External power
Main battery
O.K.
Low
Almost
exhausted
Action
Issues warning
-
message for low
voltage of the
battery pack.
Turns off the power.
Resume (with warning at time of
startup)
Forces the terminal
Warm boot (with warning at
to turn off the
time of startup)
power.
Turns off the power.
Resume (with warning at time of
startup)
Description
Power via AC Adaptor is being supplied, and charging
the battery pack is complete.
Power via AC Adaptor is being supplied, and charging
the battery pack continues.
Operating power by the battery pack is being supplied.
The battery pack has been fully charged or has a
sufficient capacity.
The battery voltage level is at 30% or less.
The battery voltage level is at 10% or less.