3. Operate the hand primer lever until air-free fuel flows
into the fuel filter bowl (2).
4. Continue operating the hand primer lever until the fuel
filter bowl is full of air-free fuel.
5. Operate the hand primer lever for an additional 20
strokes.
6. Start the engine and place throttle to 3/4 position.
NOTICE: Do not operate the starter for more than 30 s at
a time. Allow the starter to cool for 3 min between starting
attempts. Failure to allow the starter to cool may result in
starter damage.
7. Run the engine until the engine operates smoothly.
8. If the engine fails to start or shuts off shortly after start
up perform the bleeding process again.
7 - MAINTENANCE
7-40
2
NHIL17CT01304BA