Removing The Drive Backplane - Dell EMC PowerEdge R750xs Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge R750xs:
Table of Contents

Advertisement

5. DST_PA2 (PCIe/NVMe connector)
7. DST_PB2 (PCIe/NVMe connector)
Figure 48. 8 x 3.5-inch SAS/SATA backplane
1. BP_PWR_1 (PERC to backplane)
2. BP_DST_SA1 (SAS/SATA connector)
3. Front mounted front PERC connector

Removing the drive backplane

Prerequisites
CAUTION:
To prevent damage to the drives and backplane, remove the drives from the system before removing
the backplane.
CAUTION:
Note the number of each drive and temporarily label them before you remove the drive so that you
can reinstall them in the same location.
NOTE:
The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
4.
Remove the drive backplane
5. Remove all the drives.
6. If installed, disconnect the optical drive signal and power cables from the system.
7. Disconnect the drive backplane cables from the connectors on the system board.
Steps
1. Press the blue release tabs to disengage the drive backplane from the hooks on the system.
2. Lift the drive backplane out of the system.
NOTE:
To avoid damaging the backplane, ensure that you move the control panel cables from the cable routing clips
before removing the backplane.
56
Installing and removing system components
Safety
instructions.
Before working inside your
cover.
6. BP_PWR_1 (backplane power and signal cable to system
board)
system.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents