Using System Diagnostics; Dell Embedded System Diagnostics - Dell EMC PowerEdge R750xs Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge R750xs:
Table of Contents

Advertisement

2. Drive status LED indicator
3. Drive capacity label
NOTE:
If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE:
Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 47. Drive indicator codes
Drive status indicator code
Blinks green twice per second
Off
Blinks green, amber, and then powers off
Blinks amber four times per second
Blinks green slowly
Solid green
Blinks green for three seconds, amber for three seconds,
and then powers off after six seconds

Using system diagnostics

If you experience an issue with the system, run the system diagnostics before contacting Dell for technical assistance. The
purpose of running system diagnostics is to test the system hardware without using additional equipment or risking data loss.
If you are unable to fix the issue yourself, service and support personnel can use the diagnostics results to help you solve the
issue.

Dell Embedded System Diagnostics

NOTE:
The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA)
diagnostics.
The Embedded System Diagnostics provide a set of options for particular device groups or devices allowing you to:
● Run tests automatically or in an interactive mode
● Repeat tests
● Display or save test results
● Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
● View status messages that inform you if tests are completed successfully
● View error messages that inform you of issues encountered during testing
Running the Embedded System Diagnostics from the Dell Lifecycle
Controller
Steps
1. When the system is booting, press F10.
2. Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics
start executing the tests on all the detected devices.
Condition
Indicates that the drive is being identified or preparing for removal.
Indicates that the drive is ready for removal.
NOTE:
The drive status indicator remains off until all drives are
initialized after the system is powered on. Drives are not ready
for removal during this time.
Indicates that there is an unexpected drive failure.
Indicates that the drive has failed.
Indicates that the drive is rebuilding.
Indicates that the drive is online.
Indicates that the rebuild has stopped.
System diagnostics and indicator codes
147

Hide quick links:

Advertisement

Table of Contents
loading