Route And Connect Power Cords And Data Cables; Figure 40 Route For Sample Data Cables On Either Side Of The Cma Cable Capture Arm - Seagate Exos CORVAULT Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos CORVAULT:
Table of Contents

Advertisement

5. Complete the following actions to route an Ethernet cable to each of the controller modules:
a. Route the first Ethernet cable, numbered 9, to the Ethernet port on the outer controller module.
b. Route the second Ethernet cable, numbered 10, to the Ethernet port on the inner controller module.

Figure 40 Route for sample data cables on either side of the CMA cable capture arm

6. Complete the following actions to route cable groups through the cable capture arm:
a. Route the first group of five cables, numbered 1 to 4 and 9, so they lie flat as shown on the base of the open cable
capture arm.
b. Route the second group of five cables, numbered 5 to 8 and 10, so they lie flat as shown on the opposite side.
c. Make sure each cable meets the bend radius for that cable type as you properly and smoothly route all cables.
d. Rotate both cable capture arms to secure each cable group on its appropriate side. If the cables are SAS data
cables, you may need to press them downward to properly seat the cable capture arms.
7. Tighten the thumbscrew down on both cable capture arms.

Route and connect power cords and data cables

This task will maximize space, provide for minimal cable crossover, and enable in-service maintenance.
NOTE The following cable configuration is only a sample configuration and changes, based on individual system
requirements.
1
2
3
4
9
5
6
7
8
10
Chapter 4   Route power cords and data cables
45