Required equipment
CMA bracket assembly, properly installed
T10 Torx driver, 6-in length
Power cords
M3 low-profile screw, 5x2.75-in length
To route power cords from the power supply units:
1. Select both power cords from the packaging, remove the cable ties, and connect a right-angle power cord connector
to each PSU.
2. Move the CMA  bracket assembly aside to access the cable capture clip on the chassis.
3. Loosen the captive screw on cable capture clip and then raise the clip on its hinge.

Figure 35 Location of cable capture clip release screw

4. Route the outer power cord just inside the outer fan and up to the clip, allowing a minimum of slack.
5. Route the inner power cord just inside the third fan and up to the clip, allowing a minimum of slack.

Figure 36 Power cord routing up to cable capture clip

6. Ensure both cords lie smooth and flat against the chassis as you route them through the cable capture clip.
7. Lower the clip hinge, then tighten the captive screw to a torque of 5 lbf-in (.54 N-m).
42            Chapter 4   Route power cords and data cables