Figure 54 Removal of a controller fan

10. While maintaining proper static protection, remove the new controller fan module from its static-protected container.
11. Inspect the controller fan module carefully to make sure it is not damaged or bent in any way, paying particular
attention to connector pins.
12. Properly orient the controller fan module so you can grasp the handle, then orient it to its empty slot.
13. Slide the controller fan module into its empty slot until it firmly connects to the baseplane.
14. If you are replacing both controller fan modules, repeat the entire process for the second one.
15. Verify the controller fan module status LED is off and the cooling fans began spinning.
16. Replace the auxiliary bay cover, latching it firmly in place.
17. Return to the front panel of the storage enclosure and verify that the Fault-Auxiliary bay LED is not steady amber.
18. (Optional) Lower and remove the mechanical lift.
19. Facing the front panel, press both safety lock switches to release the rails.
20. Carefully exert even pressure on both sides of the storage enclosure front and continue insertion all the way into the
rack until it locks in the storage position. Do not force insertion, which could damage the rails.
21. Secure the storage enclosure chassis flanges to the rack cabinet, fastening the top captive thumbscrew on each side
until tight.

Replace a system fan module

The four (4) system fan modules provide cooling to the main bay of the storage enclosure.