78 Appendix B: Technical reference
Wire-terminal
Hardware signal
name
IN8+, IN8-
AUX_ISOIND_IN8
OUT1+, OUT1-
AUX_ISOIND_OUT1
OUT2+, OUT2-
AUX_ISOIND_OUT2
OUT3+, OUT3-
AUX_ISOIND_OUT3
OUT4+, OUT4-
AUX_ISOIND_OUT4
OUT5+, OUT5-
AUX_ISOIND_OUT5
OUT6+, OUT6-
AUX_ISOIND_OUT6
OUT7+, OUT7-
AUX_ISOIND_OUT7
OUT8+, OUT8-
AUX_ISOIND_OUT8
1. Supported inputs: interrupt/poll (M_IO_STATUS), timer clock (M_TIMER_CLOCK_SOURCE), timer arm
(M_TIMER_ARM_SOURCE), I/O command list counter source, reference latch trigger
(M_REFERENCE_LATCH_TRIGGER_SOURCE), quadrature input bit 0 or 1
(M_ROTARY_ENCODER_BITn_SOURCE), rotary decoder counter reset source
(M_ROTARY_ENCODER_RESET_SOURCE)
2. Supported outputs: user bit (M_USER_BITn), timer output (M_TIMERn), or an I/O command register bit
(M_IO_COMMAND_LISTn+M_IO_COMMAND_BITn).
Serial port connectors
The 2 serial port connectors are 9-pin, D-subminiature male connectors (DB-9
Although they are both configured for the RS-232 standard, the configuration of
the top connector can be changed to accommodate the RS-485 standard by
adjusting the unit's settings in the UEFI Setup utility. For information, refer to
Appendix C: Matrox 4Sight EV6 UEFI reference.
The top serial port connector (labeled Com1/RS-232/485) in RS-485 mode is
not terminated by default. If your configuration requires that you instantiate
termination of the RS-485 connection, refer to the RS-485 termination connector
subsection of the Pinout descriptions of internal connectors section, later in this
appendix.
1. More accurately known as DE-9.
MIL constant
Description
for auxiliary
signal
M_AUX_IO15
Isolated, industrial auxiliary signal 15 (input).
M_AUX_IO0
Isolated, industrial auxiliary signal 0 (output).
M_AUX_IO1
Isolated, industrial auxiliary signal 1 (output).
M_AUX_IO2
Isolated, industrial auxiliary signal 2 (output).
M_AUX_IO3
Isolated, industrial auxiliary signal 3 (output).
M_AUX_IO4
Isolated, industrial auxiliary signal 4 (output).
M_AUX_IO5
Isolated, industrial auxiliary signal 5 (output).
M_AUX_IO6
Isolated, industrial auxiliary signal 6 (output).
M_AUX_IO7
Isolated, industrial auxiliary signal 7 (output).
1
2
2
2
2
2
2
2
2
1
).