Matrox 4Sight EV6 Installation And Hardware Reference page 100

Table of Contents

Advertisement

100 Appendix D: Migrating auxiliary I/O connections from Matrox 4Sight GPm to Matrox 4Sight EV6
both the Matrox 4Sight EV6 auxiliary output and the serial resistor to make sure
that the voltage seen at the input of the sinking field device can reliably assure the
detection of a high logical state.
The diagram below illustrates the difference between connecting a sinking field
device to Matrox 4Sight GPm and connecting it to Matrox 4Sight EV6:
PREVIOUS:
Matrox
4Sight GPm auxiliary output wired to a sinking field device requiring a pull-up resistor
+
Up to 24V
Matrox 4Sight
in a sinking configuration
NEW: Matrox 4Sight EV6 auxiliary output wired to a sinking field device requiring a serial resistor
+
Up to 24V
Matrox 4Sight EV6 auxiliary outputs
in a
sourcing
 Note that with the above wiring modification, there will be a logical inversion to
take into consideration. The sinking field device will not detect an ON condition
when the Matrox 4Sight EV6 auxiliary output is closed.
AUX_OUTn+
AUX_OUTn-
GPm
auxiliary
outputs
AUX_OUTn+
AUX_OUTn-
configuration
INPUT
Input
sensing
COM-
Sinking ield evice
f
d
(compatible with PNP
output)
INPUT
Input
sensing
COM-
Sinking field device
(compatible with PNP
output)