72 Appendix B: Technical reference
Warning
To ensure EMC conformity, connect the chassis ground pin of your Matrox 4Sight
EV6 unit to earth.
Operating voltage and current for the auxiliary signals of Matrox 4Sight EV6.
Input signals
Output signals
Operating range
Input current
Input voltage threshold
ON voltage level
OFF voltage level
Typical OFF to ON response
Typical ON to OFF response
Maximum input frequency 12 V,
50% duty cycle
Maximum input frequency 24 V,
50% duty cycle
Operating range
Output current
ON voltage level (closed)
Typical OFF to ON response
Typical ON to OFF response
Maximum output frequency 12 V,
50% duty cycle
Maximum output frequency 24 V,
50% duty cycle
12 V - 24 V (27 V abs.max)
1.3 mA - 2.25 mA
9.4 V
- 9.6 V
IL
IH
>=10 V @ 1.3 mA
<=8 V @ 0.8 mA
0.4 μsec @ 12 V
0.2 μsec @ 24 V
0.2 μsec @ 12 V
1 μsec @ 24 V
1.25 MHz
500 kHz
12 V - 24 V (27 V abs.max)
10 mA (typical) - 100 mA (max)
1.5 V drop @ 30 mA across
AUX_IOn+ and AUX_IOn- pins.
40 μsec @ 12 V
50 μsec @ 24 V
150 μsec @ 12 V
240 μsec@ 24 V
6.1 kHz
2.5 kHz