Matrox 4Sight EV6 Installation And Hardware Reference page 104

Table of Contents

Advertisement

104 Appendix D: Migrating auxiliary I/O connections from Matrox 4Sight GPm to Matrox 4Sight EV6
The diagram below illustrates the difference between connecting a sourcing field
device to Matrox 4Sight GPm and connecting it to Matrox 4Sight EV6, without
using a pull-up resistor:
PREVIOUS: Matrox 4Sight GPm auxiliary input wired to a sourcing field device requiring serial/parallel resistors
+
Sensing
circuit
Up to 24V
Matrox 4Sight GPm auxiliary inputs
in a sinking configuration
NEW: Matrox 4Sight EV6 auxiliary input wired to a sourcing field device without resistors
+
Sensing
circuit
Up to 24V
Matrox 4Sight EV6 auxiliary inputs
in a
sinking
configuration
+V
OUT
AUX_INn+
AUX_INn-
-V
PNP ourcing field device
+V
OUT
AU INn
X_
+
AUX_ n-
IN
-V
PNP ourcing field device
s
s

Hide quick links: