1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place.
2. Make sure that the room temperature is in the range in the operating specifications.
• FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0146
User Action:
Complete the following steps until the problem is solved:
1. Check xClarity Controller (XCC) event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers/airduct
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• FQXSPMA0013N: The System [ComputerSystemElementName] has detected no memory in the
system.
This message is for the use case when an implementation has detected that memory was detected in the
system.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0794
User Action:
Please add minimum size of DIMM to operate this system.
• FQXSPMA0015L: Redundancy Lost for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Lost has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0802
User Action:
Complete the following steps until the problem is solved:
1. Please check system spec to install the part.
2. If the problem still exist, please updgrade the firmware to the latest level and restart.
50
ThinkSystem SR250 Messages and Codes Reference