Lenovo ThinkSystem SR250 Messages And Codes Reference page 120

Hide thumbs Also See for ThinkSystem SR250:
Table of Contents

Advertisement

Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0520
User Action:
Please check the identified device error in the system event log.
• FQXSPUN0019M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
1. Please check XCC web GUI to see the identified error.
2. Check system event log to fix the error.
3. If the problem still exist, please contact local service.
• FQXSPUN0023N: Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps until the problem is solved:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to
on-board TPM/TPM card error
2. Reboot the system.
3. If the error continues, contact service for further support.
• FQXSPUN0026G: Device [LogicalDeviceElementName] has been added.
This message is for the use case when an implementation has detected a Device was inserted.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
116
ThinkSystem SR250 Messages and Codes Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7y517y527y727y73

Table of Contents