Lenovo ThinkSystem SR250 Messages And Codes Reference page 160

Hide thumbs Also See for ThinkSystem SR250:
Table of Contents

Advertisement

Severity: Info
User Action:
Information only; no action is required.
• FQXPMRS0011K: Failed to change disk drives' state.
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of the RAID adapter and disk drives are both normal.
3. Verify proper physical connection of the disk drive and RAID adapter.
4. Reboot the machine and retry to change disk drives' state.
5. If the error still occurs, contact service to support.
• FQXPMSD0001M: HDD Test was interrupted by the host with a hardware or software reset
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
• FQXPMSD0002M: A fatal error or unknown test error occurred while the device was executing its
self-test
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
• FQXPMSD0003M: self-test completed having a test element that failed and the test element that
failed is not known.
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
• FQXPMSD0004M: self-test completed having the electrical element of the test failed.
Severity: Error
User Action:
156
ThinkSystem SR250 Messages and Codes Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7y517y527y727y73

Table of Contents