User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFPU0016N: A processor within the system has failed the BIST.
Severity: Error
User Action:
Complete the following steps:
1. If the processor or firmware was just updated, check the Lenovo support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFPU0017G: A processor microcode update failed.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
Processor error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFPU0018N: CATERR(IERR) has asserted on processor [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this Processor error.
2. Reboot the system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFPU0019N: An uncorrectable error has been detected on processor [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. Reboot the system.
134
ThinkSystem SR250 Messages and Codes Reference