Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0446
User Action:
Reflash or update XCC firmware. If the problem still exit, please contact service to support
• FQXSPUP4000I: Please ensure that the Management Controller [arg1] is flashed with the correct
firmware. The Management Controller is unable to match its firmware to the server.
This message is for the use case where a Management Controller firmware version does not match the
server.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0031
User Action:
Update the XCC firmware to a version that the server supports. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code.
• FQXSPUP4001I: Flash of [arg1] from [arg2] succeeded for user [arg3] .
This message is for the use case where a user has successfully flashed the firmware component (MC Main
Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure
Power Backplane, Integrated System Managem
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0035
User Action:
Information only; no action is required
• FQXSPUP4002I: Flash of [arg1] from [arg2] failed for user [arg3].
This message is for the use case where a user has not flashed the firmware component from the interface
and IP address due to a failure.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0036
User Action:
Information only; no action is required
• FQXSPUP4003I: [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the
[arg3] firmware.