Installation and Connection

3.2.1 Identification of the Power and Grounding Terminals

NOTE!
Models CFW110006B2 and CFW110007B2 may operate with single-phase power supply without
rated output current derating. In this case, the single-phase power supply may be connected to two
of any input terminals.
Models CFW110006S2OFA, CFW110007S2OFA, and CFW110010S2 not operate with three-phase
voltage. In this case, the single-phase power supply shall be connected to terminals R/L1 and S/L2.
R/L1, S/L2, T/L3: AC power supply.
DC-: this is the negative potential terminal in the DC Link circuit.
BR: braking resistor connection.
DC+: this is the positive potential terminal in the DC Link circuit.
3
U/T1, V/T2, W/T3: motor connection.