Metering Audit Tests - Hartridge CRi-PC Operating And Servicing Manual

Common rail injector test stand
Hide thumbs Also See for CRi-PC:
Table of Contents

Advertisement

CRi-PC Operating and Servicing Manual
5.3.4

Metering Audit Tests

Refer to Figure 5.4
Figure 5.4 Metering Audits (Leak Test)
The Start function keys at the bottom of the window will start the audit tests as listed in the
window.
The
Previous Step
Apply Step
Next Step
Stop Metering
Stop Test
Metering audits 2, 3, and 4 should be run using the audit testplan provided. Load the Metering
Audit testplan for the injector type fitted, e.g. "Bosch_MeteringAudit.cpf". Before starting any
audit, run the "PURGE" condition for a couple of minutes to ensure the system is clear of air
and the firing order has been learnt. Then select the "AUDIT" condition to run audits 2, 3 and
4.
94
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
keys provide the following functions:-
HARTRIDGE LIMITED
HL037 (EN), Issue 13, AT714, 05/14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents