Install Injector In The Clamping Fixture & Clamp - Hartridge CRi-PC Operating And Servicing Manual

Common rail injector test stand
Hide thumbs Also See for CRi-PC:
Table of Contents

Advertisement

HARTRIDGE LIMITED
If the resistance measured is within acceptable limits disconnect the resistance cable from the
injector and proceed as follows.
4.3.3
Install Injector in the Clamping Fixture & Clamp
Refer to Figure 4.10
Figure 4.10 shows a general schematic of the injector installation. The exact parts required
will depend on the injector type - full details are given in Technical Bulletin 195/11. Select the
right parts for the injector you have and mount as shown.
NOTE: Kit numbers given in Technical Bulletin 195/11must be given the suffix '/C' e.g.
NOTE:
The clamp block screws 'A' should be tightened to a torque of 25Nm.
NOTE:
HL037 (EN), Issue 13, AT714, 05/14
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
Figure 4.8 Injector Connectors
Figure 4.9 Resistance Check
HK9xx/C. kits with suffix '/C' have sufficient parts for 1 injector. Kits without the suffix
have parts for 4 injectors and are used for AVM2-PC and 4-line CRi-PC machines.
Remove any sealing washers from the injector nozzle and use the seals supplied in the
relevant Nosepiece Adaptor Kit.
The clamping load is set by the distance D between the upper and lower blocks. For the
majority of injectors a 9kN clamp load is recommended, therefore the 9kN Spacer
NTA5002 should be fitted unless advised otherwise.
CRi-PC Operating and Servicing Manual
2
1
79