13. Switch off the main electrical isolator by rotating the switch shaft 90 degrees anti-
clockwise.
14. Switch off and disconnect the electrical supply at the wall.
15. Swap over any TWO of the of the mains supply wires going to the isolator switch.
16. Re-apply electrical power to the test stand and check the motor rotation as described
in this procedure.
17. When the rotation is correct:
Switch off the main electrical isolator.
Close the electrical cabinet door, ensuring that the '0' symbol on the switch operating
handle is visible as the door is closed. This is to ensure correct engagement between
the isolator switch shaft and the handle.
1
20
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
Figure 2.7 Motor Rotation