Hartridge CRi-PC Operating And Servicing Manual page 101

Common rail injector test stand
Hide thumbs Also See for CRi-PC:
Table of Contents

Advertisement

HARTRIDGE LIMITED
Change the Test Fluid Filter (Hartridge Number 8850082)
8. Open the injector access door to access the test fluid filter (Figure 5.8). The filter hangs
on an aperture to the right of the injector clamp. To remove the filter, simply lift the filter
up and away from the aperture.
9. Remove the pipe loop (L) (Figure 5.9) and fit it to the new filter.
10. Disconnect the inlet pipe from the pump (I) and connect it to the correct port on the new
filter - identified with a green dot (I).
11. Disconnect the outlet pipe (O) and connect it to the correct port on the new filter.
HL037 (EN), Issue 13, AT714, 05/14
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
Figure 5.7 Magnet Filter
Figure 5.8 Fluid Filter in Situ