Function Keys (Alternate Menu); Main Screen Areas - Hartridge CRi-PC Operating And Servicing Manual

Common rail injector test stand
Hide thumbs Also See for CRi-PC:
Table of Contents

Advertisement

HARTRIDGE LIMITED
F6 Testplan editor:
Refer to Figure 4.2
Launches the MAGMAH parameter editor which is used to generate / modify testplans. For
further details of the parameter editor refer to section 4.5.
F7 Print:
Refer to Figure 4.3
Displays a dialog to print. A drop down menu allows selection of the printer to be used -either
the optional internal strip printer or an externally mounted desktop printer (not supplied).
The type of printout can be selected, either a short summary report or a full report.
F8 Results viewer:
Refer to Figure 4.14
Displays a results screen where previous results can be loaded / viewed.
F9 Measure Resistance
Refer to Figure 4.9
Enables the resistance of the injector coil to be measured and displayed on screen. The
appropriate resistance test cable should be connected for this.
NOTE
F10 Status / diagnostic:
Refer to Figure 4.4
Displays the status dialog –each status box will display a red cross if there is a fault.
F11 Reset:
Resets the software as per power up.
F12 Alternate Menu:
Toggles between the main and alternate key functions
4.2.2

Function keys (Alternate Menu)

F7 (alternate menu) Production setup:
Refer to Figure 4.16
Displays the Production Setup Dialogue. This is shown for reference only. All settings here
are locked and require a log-on password to enable alteration.
F8 (alternate menu) Owner details:
Refer to Figure 4.5
Displays the Owner Details Dialogue.
F10 (alternate menu) Backleak audit:
Refer to Figure 5.5
Displays the Backleak audit screen that enables the HK901 Backleak Flow Module (if fitted) to
be audited.
F11 (alternate menu) Metering audit:
Refer to Figure 5.4
Displays the Metering audit screen that enables the metering unit to be audited.
4.2.3

Main Screen Areas

Area 1:
Basic injector characteristics -
Shows the testplan loaded, the injector type loaded and the basic electrical characteristics:
Supply Voltage; Hold Current; Pull-in Current and Maximum Pull-in Pulse Width.
Also indicates if the fixture is clamped and if the drive motor is running.
Area 2:
Test conditions -
HL037 (EN), Issue 13, AT714, 05/14
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
Resistance measurement is only valid for solenoid coil injectors, not for piezo injectors.