12. Hang the new filter on the filter bracket.
L
Change the pump suction filter (Hartridge Number A129C123)
13. Open the side panel (see section 5.1) to access the test fluid filter. The filter is pressed
on to the suction pipe and hangs in the oil at the back right hand side of the tank. Pull off
and replace.
Fill with test fluid
14. Refill the tank as described in section 2.6 with clean test fluid to ISO4113 specification.
15. Switch on the test stand and ensure the air supply is connected. The fluid circulation
pump should start. Check around the filter for leaks.
100
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
O
Figure 5.9 Fluid Filter Connections
HARTRIDGE LIMITED
I
HL037 (EN), Issue 13, AT714, 05/14