Error History; Temporary Switch-Off - Beretta EXCLUSIVE R Installer And User Manual

Hide thumbs Also See for EXCLUSIVE R:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
EXCLUSIVE
--
water pressure high - check the system
--
boiler board communication lost
--
BUS 485 communication lost
List of combustion faults
ERROR
ERROR MESSAGE
CODE
E021
E022
E023
E024
E067
E088
E097
E085
incomplete combustion
E094
incomplete combustion
E095
incomplete combustion
E058
mains voltage fault
E065
current modulation alarm
E086
obstruction fumes alarm
Warning lights
BOILER STATUS
Power-on
Vent cycle
OFF status
No heat request (stby)
Transitional ignition/
overtemperature
Presence of flame
Chimney sweep
Screed heater

5.16 Error history

The ERROR HISTORY function is automatically enabled only after the
machine has been powered up for at least 2 consecutive hours, during
this period of time any alarms that arise would not be saved in the "error
history".
The alarms can be displayed in chronological order, from the most recent
to the oldest, up to a maximum of 50 alarms; to display the alarm history:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select ERROR HISTORY with the "up" and "down" keys, confirming
the selection
- scroll through the error history with the "up" and "down" keys; for each
alarms a sequential number is displayed, an error code and the date and
time the alarm occurred.
TECHNICAL
TECHNICAL
RANGE RATED
RANGE RATED
CALIBRATION
CALIBRATION
COMBUSTION ANALYSIS
SWEEPER
EXHAUST PROBE RESET
EXHAUST PROBE RESET
ERROR HISTORY
ALARM HISTORY
INSTALLER
INSTALLER
It is possible to return to the start page at any time by keeping the key
"back" pressed for at least 2 seconds.
Note: once enabled, the ERROR HISTORY function can no longer be
disabled; there is no procedure for resetting the rror history.
If an alarm repeats consecutively, it is saved only once.
24
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
RED LED
GREEN LED
flashing
flashing
0.5 sec. on/1 sec. off
0.5 sec. on/1 sec. off
flashing
0.3 sec. on/0.5 sec. off
flashing
0.3 sec. on/0.5 sec. off
flashing
0.3 sec. on/0.5 sec. off
ON
ON
flashing
flashing
1 sec.on/1 sec. off
1 sec.on/1 sec. off
1 - 10:30 18/11/2013
E030
FAN ERROR
FAN ANOMALY
USE ARROW KEYS TO SEE OTHER
USE ARROW KEYS
ANOMALIES
TO SEE OTHER ANOMALIES
flashing
0.5 sec. on/0.5 off
ON
ON
LED
LED
RED
GREEN
ON
ON
These are temporary alarms that if they occur 6 times in an hour they
ON
become definitive; the alarm E097 is displayed and is followed by post-
ON
purging for 45 seconds at the fan's maximum speed.
It is not possible to release the alarm before the end of the post-purging
ON
unless the boiler's power supply is switched off.
ON
ON
These are temporary alarms that if they occur 3 times in an hour they
ON
become definitive; the last error to occur is displayed and is followed by a
ON
post-purging of 5 minutes at the fan's maximum speed.
It is not possible to release the alarm before the end of the post-purging
ON
unless the boiler's power supply is switched off.
ON
These are temporary faults that restrict the ignition cycle.
ON
Temporary fault reported during the post ventilation. It is maintained a post
ON
ventilation of 5 min at maximum fan speed.
RED and GREEN
flashing
0.5 sec. on/0.5 sec. off

5.17 Temporary switch-off

In the event of temporary absences (weekends, short breaks, etc.) set the
status of the boiler to OFF
While the electrical supply and the fuel supply remain active, the boiler is
protected by the systems:
- heating anti-freeze: this function is activated if the temperature
measured by the flow sensor drops below 5°C. A heat request is
generated in this phase with the ignition of the burner at minimum output,
which is maintained until the outlet water temperature reaches 35°C;
- domestic hot water anti-freeze (only if water tank connect): the
function starts if the temperature measured by the water tank probe falls
below 5°C. A heat request is generated in this phase with the ignition of
the burner at minimum output, which is maintained until the outlet water
temperature reaches 55°C.
b
The activation of the ANTI FREEZE function is indicated by a scrolling
message on the foot of the REC10 display.
- circulator anti-locking: the circulator activates every 24 hours of
stoppage for 30 seconds.
transitional
transitional
transitional
DESCRIPTION OF TYPE OF ALARM
NOTES
The red and green LEDs come on at the same time
The red and green LEDs come sequentially one at a time
Only if the flame is present
The red and green LEDs come on alternately
.
BOILER
BOILER
OFF
OFF
HOT WATER ONLY
SUMMER
HEATING AND HOT WATER
WINTER