Error Behaviour Of The Outputs; Restore Factory Settings - TESTO 6457 Instruction Manual

Compressed air meter
Table of Contents

Advertisement

9.5.10 Error behaviour of the outputs

Select [FOU1] and set error behaviour for output 1:
On
= Output 1 switches ON in the event of an error.
OFF
= Output 1 switches OFF in the event of an error.
OU
= Output 1 switches irrespective of the error as
defined with the parameters
Select [FOU2] and set error behaviour for output 2:
Switching output:
On
= Output 2 switches ON in the event of an error.
OFF
= Output 2 switches OFF in the event of an
OU
= Output 2 switches irrespective of the error as
Analog output:
On
= The analog signal goes to the upper error
OFF
= The analog signal goes to the lower error
OU
= The analog signal corresponds to the
Note

9.5.11 Restore factory settings

Select [rES]
Briefly press [●]
Press and hold [▲] or [▼].
→ [----] is displayed.
Briefly press [●].
→ The instrument carries out a reboot.
Note
error.
defined with the parameters
value (
4.3.3).
value (
4.3.3).
measured value.
If [ou] = Imp (consumption quantity monitoring) was selected, the
parameter [FOUx] is not available. The pulses are provided
irrespective of the error.
13 Factory settings. We recommend noting down your own
individual settings in this table before implementing this function.
Menu OUT1:
[FOU1]
Menu OUT2:
[FOU2]
Menu EF:
[rES]
55