9.3.2
Quantity monitoring by preset counter
OUT1 or OUT2
Select [SELx] and set FLOW
Select [oux] and adjust the pulse output: ImP
Select [ImPSx] and set the flow quantity at which
output x switches.
Select [ImPRx] and set NO.
9.3.3

Manual counter reset

Select [rTo] and set rES.T.
→ The totaliser is reset to zero
9.3.4

Time-controlled counter reset

Select [rTo] and set the required value
(intervals of hours, days or weeks).
→ The totaliser is automatically reset with the value now set.
9.3.5

Deactivating counter reset

Select [rTo] and set OFF.
→ The totaliser is only reset after overflow.
50
Menu OUTx:
[SELx]
[oux]
[ImPSx]
[ImPRx]
Menu EF:
[rTo]
Menu EF:
[rTo]
Menu EF:
[rTo]