Air Regulator - Panduit PATMFM4.0 Operation Manual

Pat4.0 flush mount fixture
Hide thumbs Also See for PATMFM4.0:
Table of Contents

Advertisement

© Panduit Corp.
2020
Table-Top Template General Overview:
STEP 1:
DRILL x8 5/64"
THROUGH HOLES
INTO WORK
SURFACE.
(MARKED "A")
Table 2F: Minimum Work Surface Specification
2G: Air Regulator
The PATMFM4.0 Air Regulator is designed to split and effectively "branch" the air regulator connection
already utilized by the PAT4.0 Fully Automatic Cable Tie Installation System. This branching air regulator
connects between the PAT4.0 System's Air Regulator output and PAT4.0's air input fitting to provide a
reduced operating pressure utilized by the PATMFM4.0 Fixture. The PATMFM4.0 Air Regulator is
adjustable and should be set to the recommended output specification (Table 4A) before connecting to and
operating the Fixture. Confirm this output pressure via the Air Regulator's pressure gauge.
Air Regulator General Overview:
MAX: DO NOT EXCEED 45 PSI (3,1 bar)
OPERATION MANUAL
MIN. DISTANCE
FROM LEADING
EDGE OF WORK
SURFACE.
Dimension
Length
Width
Depth
TO PATMFM4.0
AIR INPUT FITTING
MIN: 40 PSI (2,8 bar)
STEP 2:
REMOVE MAT'L
WITHIN SOLID
PERIMETER.
22.0" (559mm)
18.0" (457mm)
1.00" (25.4mm)
TO PDM4.0 AIR
REGULATOR OUTPUT
MIN: 65 PSI (4,5 bar)
MAX: DO NOT EXCEED 85 PSI (5,8 bar)
TO PDM4.0
AIR INPUT FITTING
MIN: 65 PSI (4,5 bar)
MAX: DO NOT EXCEED 85 PSI (5,8 bar)
8
PATMFM4.0
ENGLISH
WORK SURFACE
DEPTH MUST BE
AT MIN. 1.00"
Value