Fixture Tool Cage - Panduit PATMFM4.0 Operation Manual

Pat4.0 flush mount fixture
Hide thumbs Also See for PATMFM4.0:
Table of Contents

Advertisement

© Panduit Corp.
2020
F. Electronics Enclosure Cover
G. Air-Regulator Input Fitting
H. EI Communication Port
I.
Tool Cage air-line Output Quick-Connector
Table 2A: PATMFM4.0 Fixture Overall Specification
Max Height Relative to Work Surface
2B: Fixture Tool Cage
The Fixture Tool Cage allows PAT1M4.0 and PAT1.5M4.0 Handheld Cable-Tie Installation Tools to be
mounted and installed into the PATMFM4.0 Table-Top Fixture. Installation of a Hand Tool is preceded by
removing the Rear Lower Tool Support (Item C) via the two thumbscrews (Item D). With the Rear Support
removed, a Hand Tool can be inserted and aligned relative to the Top and Bottom Front Tool Supports
(Item(s) A, B). Once a selected Tool is mounted into the Tool Cage and the Rear Support re-installed, the
Cage can be mounted onto the PATMFM4.0 Fixture, thus suspending the Tool such that only the top portion
of the Tool protrudes from the work surface. An airline (Item E) that exits the tool Cage is connected to the
PATMFM4.0 Fixture and delivers a controlled burst of air to the Actuation Trigger (Item G), engaging the
Tool Trigger (Item G) itself and beginning a cycle. Once complete, air is exhausted, the Actuation Trigger
retracts and the Tool is reset for a new cycle.
Fixture Tool Cage General Overview:
A
B
OPERATION MANUAL
Dimension
Length
Width
Height
G
19.32" (491mm)
9.27" (235mm)
6.53" (166mm)
F
H
D
E
C
4
PATMFM4.0
Value
1.79" (45mm)
ENGLISH