PATMFM4.0 Fixture with all Connections Installed:
3. Unlatch the actuation paddle from its "storage" orientation as shown below. Operation of the Fixture system
is based on triggering the paddle from this upright "operational" orientation. The paddle actuates a Tool cycle
once it has traveled, at minimum, 15 degrees past this upright orientation. Actuation can be performed with a
knuckle of the right hand, the index finger of the right hand, the right hand altogether or with the workpiece itself.
(The paddle does not need to be held in the "actuation" position during a cycle. A simple yet deliberate "tap" is
all that is required to initiate and complete a cycle).
Actuation Paddle Unlatch Detail:
4. Power on the PAT4.0 System and verify that the Operator Menu is displaying "Ready" in green bar on
the screen as shown below. The PAT1M4.0 and PAT1.5M4.0 Tools can only dispense cable ties if the
Operator Menu is in the ready state.
The Operator Menu in the "Ready" state: