8: TROUBLESHOOTING

8A: Error Message Troubleshooting
ERROR
Ties are not delivered reliably to the
Tool.
Cycle does not initiate upon Paddle
Actuation.
Cycle does not begin. Air is heard
leaving the fixture when actuated.
Cycle begins and Tool jaws close, but tie
is not fed.
(Additional errors may be PAT4.0, PAT1M4.0 and PAT1.5M4.0 specific. Please refer to the PAT4.0 Operation Manual for
troubleshooting support).
OPERATION MANUAL
POSSIBLE CAUSE
A. Improperly routed PHM Feeder
Hose.
B. Insufficient air pressure supplied to
PAT4.0.
A. Improperly seated EI
Communication Cable.
B. Improperly connected supply-side
airline.
A. Improperly connected Tool Cage
airline.
A. Insufficient actuation pressure
applied to Tool trigger.
B. PAT1M4.0 or PAT1.5M4.0 worn
trigger pressure switch.
31
CORRECTIVE ACTION
A. 1. Confirm that the PHM Hose is
routed correctly per the PAT4.0
Operation Manual.
B.1. Refer to the PAT4.0 Operation
Manual for air pressure specifications
and troubleshooting.
A.1. Confirm that both ends of the
Communication Cable are properly
seated in their respective ports. Check
that no debris is present between
these two connections.
B.1. Check to ensure that the
PATMFM4.0 Air Regulator is properly
connected to both the PAT4.0 Air
Regulator and the PATMFM4.0 (Pg. 22).
A. 1. Confirm that the Tool Cage airline
is properly connected to the
Electronics Enclosure, located on the
underside of the PATMFM4.0 Fixture
(Pg. 21).
A. 1. Confirm the Air Regulator is
outputting the correct operating
pressure (Pg. 13).
B. 1. Refer to the applicable PAT1M4.0
or PAT1.5M4.0 Operation Manual for
servicing information.
PATMFM4.0
ENGLISH