Panduit PATMFM4.0 Operation Manual page 23

Pat4.0 flush mount fixture
Hide thumbs Also See for PATMFM4.0:
Table of Contents

Advertisement

© Panduit Corp.
2020
2. Connect the opposite end of the EI Communication Cable to the underside of the Fixture Assembly.
The corresponding connector is between the Tool Cage air output supply quick-connector and the
PATMFM4.0 Fixture's air input fitting. Use a Philips head screwdriver to retain this connection.
Connecting EI Communication Cable to PATMFM4.0 Fixture:
3. Disconnect the air supply to the PAT4.0. To this PAT4.0 air supply's quick connect fitting, insert the
PATMFM4.0 Air Regulator's corresponding fitting. Install the PATMFM4.0 Air Regulator onto the
PAT4.0 system.
(The PATMFM4.0 Air Regulator "branches" the airline input between the infrastructure air supply and
the PAT4.0. The over-braided hose extending from the PATMFM4.0 Air Regulator will connect to the
Fixture in the next step).
Branching PATMFM4.0 Air Regulator Installation Detail:
OPERATION MANUAL
PAT4.0 AIR INPUT FITTING
WA29653C01 AIR REGULATOR – PATMFM4.0
MIN: 40 PSI (2,8 bar)
MAX: DO NOT EXCEED 45 PSI (3,1 bar)
TO PATMFM4.0 TOOL FIXTURE
PAT4.0 AIR REGULATOR OUTPUT
MIN: 65 PSI (4,5 bar)
MAX: DO NOT EXCEED 85 PSI (5,8 bar).
22
PATMFM4.0