Preparing To Upgrade The Imagepro Unit; Uploading Files To The Imagepro Unit - Barco ImagePRO-SDI Installation Manual

Multi format image processor
Table of Contents

Advertisement

2.
Find the Folsom Research folder and select ImagePRO Flash File Loader.

Preparing to Upgrade the ImagePRO Unit

1.
Plug the DB-9 male connector into the port labeled "RS-232 on the back of the ImagePRO unit.
2.
Make sure the other end of the cable is attached to the available COM port on the back of the computer
performing the upgrade.
3.
In the loader program, click on the RS232 Config menu and select COM Port.
4.
In the Communication Settings window, select the COM port the ImagePRO Remote port is attached to by
clicking on the appropriate COM # choice.
5.
The ImagePRO Remote port defaults to a baud rate of 38400 baud (38.4K).

Uploading Files to the ImagePRO Unit

1.
Once communications have been established and verified, click on the "Open script file to read and upload"
button to begin the upgrade process.
2.
Browse to the location where the "CompleteLoad.sld" file is located and click on it. Then click on "Open" to
start transferring the files to the ImagePRO.
3.
A TRANSFER STATUS box will open and show the status of the upload as it progresses.
4.
After a few minutes, the loader utility will inform the user that the process is complete.
5.
Once this is done, it is recommended that the entire system be powered cycled. You can also close the
loader utility at this time.
6.
Verify the new software is in the system by looking for the version number in the Setup Tech Support
menu.
7.
Once you have verified the version number, it is recommended that a factory reset be performed. This is
done by going to the Setup Menu and selecting Factory Reset.
98
ImagePRO – Multi Format Image Processor
Manual # 26-0302000-00 / Revision E