4.2

A List of Commands

Execution Modes and User Levels

Setting Commands

Command Function
Name
SR
Sets the input range.
VB
Sets the bias.
VL
Sets the calibration correction (/CC1 option).
SA
Sets the alarm.
SN
Sets the unit.
Sets the chart speed.
SC
SD
Sets the date and time.
Sets the dot printing interval (dot model).
VT
SZ
Sets zone recording.
Sets the partial expanded recording.
SP
VR
Turns ON/OFF the recording on each channel.
ST
Sets the tag.
SG
Sets the message.
SE
Sets the secondary chart speed
(used by the remote control function (/R1 option)).
SV
Sets the moving average (dot model).
Sets the input filter (pen model).
SF
BD
Sets the alarm delay time.
VF
Sets the brightness of the display (VFD) and internal
illumination.
TD
Sets the DST.
SS
Sets the DST. (Can be used on the µR10000 with system Run mode
version 1.02 or earlier)
Sets the computing equation (/M1 option).
SO
SK
Sets the computation constant (/M1 option).
SJ
Sets the timer used in TLOG computation (/M1 option).
VD
Sets the data display screen.
CM
Sets the communication input data (/M1 option).
FR
Sets the acquiring interval to the FIFO buffer.
VH
Sets the batch number and lot number (/BT1 option).
VC
Sets the batch comment (/BT1 option).
VP
Turns Start printout/End printout ON/OFF (/BT1 option).
VA
Sets the Start printout/End printout action (/BT1 option).
VM
Sets the message format (/BT1 option).
IM 04P01B01-17E
Execution Modes
The recorder has two execution modes. Each command is specified to be used in a
particular execution mode. If you attempt to execute a command in a mode that is
different from the specification, a syntax error occurs. Use the DS command to switch to
the appropriate mode, and then execute the command. Query commands can be
executed in either mode.
• Basic Setting mode
Measurement/computation is stopped and settings are changed in this mode.
• Run mode
Run mode collectively refers to Operation mode and Setting mode of the recorder.
User Levels
The administrator and user specifications in the table indicate the user level that is specified
using the login function for Ethernet communications. For details, see section 1.1.
Execution Mode
Administrator User Page
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Run mode
Yes
Yes: Command usable
No: Command not usable
4
No
4-10
No
4-11
No
4-11
No
4-11
No
4-12
No
4-13
No
4-13
No
4-13
No
4-13
No
4-13
No
4-14
No
4-14
No
4-14
No
4-14
No
4-14
No
4-14
No
4-14
No
4-14
No
4-15
No
4-15
No
4-15
No
4-15
No
4-15
No
4-16
No
4-18
No
4-18
No
4-18
No
4-18
No
4-19
No
4-19
No
4-19
4-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents