Node model
H610S
Steps
1. Match the slot number of the failed drive from
the Element UI with the number on the
chassis.
The LED on the failed drive is lit amber.
2. Remove the bezel.
3. Press the release button, and remove the
failed drive as shown in the following
illustration:
Ensure that the tray handle
is fully open before you
attempt to slide the drive
out of the chassis.
4. Slide the drive out, and place it on a static-
free, level surface.
5. Press the release button on the replacement
drive before you insert it into the drive bay.
The drive tray handle springs open.
6. Insert the replacement drive without using
excessive force.
When the drive is inserted fully, you hear a
click.
7. Close the drive tray handle carefully.
Reinstall the bezel.
Notify NetApp Support about the drive
replacement.