NetApp HCI Manual page 249

Table of Contents

Advertisement

"nodes": [
  {
 
"bmcDetails": {
 
"bmcAddress": "10.111.0.111",
 
"credentialsAvailable": true,
 
"credentialsValidated": true
 
},
 
"chassisSerialNumber": "111930011231",
 
"chassisSlot": "D",
 
"hardwareId": "123a4567-01b1-1243-a12b-11ab11ab0a15",
 
"hardwareTag": "00000000-0000-0000-0000-ab1c2de34f5g",
 
"id": "e1111d10-1a1a-12d7-1a23-ab1cde23456f",
 
"model": "H410C",
3. Run the compute node firmware upgrade:
a. Open the hardware service REST API UI on the management node:
https://[management node IP]/hardware/2/
b. Click Authorize and complete the following:
i. Enter the cluster user name and password.
ii. Enter the client ID as mnode-client.
iii. Click Authorize to begin a session.
iv. Close the authorization window.
c. Click POST /nodes/{hardware_id}/upgrades.
d. Click Try it out.
e. Enter the hardware host asset ID
f. Do the following with the payload values:
i. Retain the values
are performed on the node and the ESXi host is set to maintenance mode.
ii. Enter the cluster controller ID
iii. Enter the package name and package version you saved from a previous step.
("hardwareId"
"force": false
and
("controllerId"
saved from a previous step) in the parameter field.
"maintenanceMode": true"
saved from a previous step).
so that health checks