3. Select the IPMI tab.
4. Select BMC Network Configuration and press Enter.
5. Choose Yes and press Enter.
6. Select Configuration Address Source and press Enter.
7. Choose Static and press Enter.
8. Select Station IP address and enter a new IP address for the IPMI port. Press
9. Select Subnet mask and enter a new subnet mask for the IPMI port. Press
10. Select Gateway IP address and enter a new gateway IP address for the IPMI port. Press
finished.
11. Connect one end of an Ethernet cable to the IPMI port and the other end to a switch.
The IPMI port for this node is ready to use.
12. Repeat this procedure for any other NetApp HCI nodes with IPMI ports that are not configured.
Change the default IPMI password for H410C and H410S nodes
You should change the default password for the IPMI administrator account on each compute and storage
node as soon as you configure the IPMI network port.
Before you begin
You have configured the IPMI IP address for each compute and storage node.
Steps
1. Open a web browser on a computer that can reach the IPMI network and browse to the IPMI IP address for
the node.
2. Enter the user name
3. Upon logging in, click the Configuration tab.
4. Click Users.
5. Select the
ADMIN
6. Select the Change Password check box.
7. Enter a new password in the Password and Confirm Password fields.
8. Click Modify, and then click OK.
9. Repeat this procedure for any other NetApp HCI H410C and H410S nodes with default IPMI passwords.
Change the default IPMI password for H610C, H615C, and H610S nodes
You should change the default password for the IPMI administrator account on each compute and storage
node as soon as you configure the IPMI network port.
Before you begin
You have configured the IPMI IP address for each compute and storage node.
Steps
ADMIN
and password
user and click Modify User.
ADMIN
in the login prompt.
Enter
when finished.
Enter
when finished.
Enter
when