5.3 Battery Maintenance

Battery inspection
Proper battery condition is essential to good machine performance and operational safety. Improper
fluid levels or damaged cables and connections can result in component damage and hazardous
conditions.
Note: this inspection is not required for machines with sealed or non-maintainable batteries.
Check electrolyte level of the battery every two weeks. Fully change the battery before adding water. If
the electrolyte level is much higher than the plate, then no need to add water.
Electrocution hazard
Contact with hot or live circuits may result in death or serious injury. Remove all rings, watches and
jewelry.
Body injury hazard
Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with
baking soda and water.
Note: the battery should be fully charged before this inspection.
a)
Only qualified riggers should rig the machine;
b)
Only certified crane operators should lift the machine and only in accordance with the applicable
crane regulations;
c)
Be sure that the battery hold-down brackets are in place and secure.
Note: Adding terminal protectors and a corrosion preventative sealant will help eliminate the
corrosion on the battery terminals and cables.