Download Print this page

Interface Status - Feig Electronic OBID i-scan ID ISC PRHD102 Manual

Standard-reader

Advertisement

®
OBID i-scan
Firmware activation required:
0x17
The firmware must be activated first using ISOStart demo program and the command "Set
Firmware Upgrade". The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
Hex-value
0x80
Unknown Command:
The Reader does not support the selected function.
0x81
Length-Error:
Protocol is too short or too long
0x82
Command not available:
A Host command was sent to the Reader in the Scan Mode.
The command with More bit does not correspond with the last command
0x83
RF communication error:
This error indicates that there is an error in communication between the Transponder and the Reader.
Reason for this can be:
Timeout for Transponder communication. "Transponder-Response-Time" in
Interface
The collision handling algorithm was not continued until no collision is detected, reasons
for the break:
0x94
More Data:
There are more Transponder data sets requested than the response protocol can transfer
at once.
0x95
Tag Error
A Tag error code was sent from the transponder. The Tag error code is shown in the fol-
lowing byte.
Tag Error-Code for ISO15693 Transponder
Hex-value
0x01
The command is not supported, i.e. the request code is not recognized
0x02
The command is not recognized, for example: a format error occurred
0x03
The option is not supported
0x0F
Unknown error
0x10
The specified block is not available (doesn't exist)
0x11
The specified block is already locked and thus cannot be locked again
0x12
The specified block is locked and its content cannot be changed
0x13
The specified block was not successfully programmed
0x14
The specified block was not successfully locked
0xA0 - 0xDF Custom command error codes
all others
reserved for future use
FEIG ELECTRONIC GmbH
Manual
is to short.
Response error code definition
Page 120 of 125

Interface Status

ID ISC.PRHD102
4.2. CFG1:
H71101-2e-ID-B.doc

Advertisement

loading