Download Print this page

Feig Electronic OBID i-scan ID ISC PRHD102 Manual page 24

Standard-reader

Advertisement

®
OBID i-scan
1
BAUD
: (HostInterface.Serial.Baudrate)
By means of this byte the baud rate of the asynchronous interface can be defined.
0x05:
4800 baud
0x06:
9600 baud
0x07:
19200 baud
0x08:
38400 baud
0x09:
57600 baud
0x0A:
115200 baud
0x0B:
230400 baud
Note:
Changing of BAUD only becomes effective after writing / saving configuration
block CFG1 to EEPROM and a reset of the Reader.
The Reader sets the baud rate to 38400 baud, if the user sets an invalid baudrate.
Not available by the USB-Reader
2
TRANS-FORM
: (HostInterface.Serial...)
By means of this byte, several parameters for the data transmission format of the asyn-
chronous interface can be defined.
Bit:
Function:
P: (HostInterface.Serial.Parity)
Kind of Parity
b00:
b01:
b10:
b11:
D: (HostInterface.Serial.Databits)
Number of Data Bits
b0:
b1:
S: (HostInterface.Serial.Stopbits)
Number of Stop Bits
b0:
b1:
2
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.
FEIG ELECTRONIC GmbH
7
6
5
0
0
0
non Parity
even Parity
odd Parity
- do not use -
8 Data Bits
- do not use -
1 Stop Bit
- do not use –
Page 24 of 125