Download Print this page

Feig Electronic OBID i-scan ID ISC PRHD102 Manual page 93

Standard-reader

Advertisement

®
OBID i-scan
b1:
UID_LNG:
Is a optional parameter and depends on the setting of UID_LF (see MODE). UID_LNG de-
fines the length of the following UID field.
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
Function
BANK_NR:
In case of Class 1 Gen 2 Transponder BANK_NR is defined as follows:
b00
b01
b10
b11
A_FLAG:
Indicates whether the reader tries to read a Gen 2 tag in Secured State. If
A_FLAG is set the protocol contains the access password.
A_FLAG:
b0
b1
ecute access command
A_PW_LNG:
Length of Access Password.
A_PW:
Access password which is used to access to the secured state of the Tag.
DB-ADR:
First block number to be read. Depending on EXT_ADR First block can be any value be-
tween 0 and 255 or 0 and 65535.
DB-N:
Number of data blocks to be written to the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface receiver buffer
size RX-BUF. The maximum number of DB-N is:
(RX-BUF - 20 )/(DB-Size)
FEIG ELECTRONIC GmbH
Transponder memory addressing is done by BANK and 2 byte DB-ADR
Field
7
6
A_FLAG
0
reserved
EPC memory bank
TID memory bank
User memory bank
no access password in protocol
access password and access password length in protocol. Reader ex-
e.g. Block size 4 (DB-N = (280 – 20) / 4 = 65)
Manual
5
4
0
0
Page 93 of 125
ID ISC.PRHD102
3
2
1
0
0
H71101-2e-ID-B.doc
0
BANK_NR

Advertisement

loading